C613-50170-01 Rev B
Command Reference for x510 Series
307
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
LUGGABLES
AND
C
ABLING
C
OMMANDS
FIBER
-
MONITORING
INTERVAL
fiber-monitoring interval
Overview
Use this command to configure the fiber monitoring polling interval in seconds for
the port. The optical power will be read every <interval> seconds and compared
against the calculated threshold values to see if a log message or other action is
required.
Use the
no
variant of this command to reset the polling interval to the default (5
seconds).
Syntax
fiber-monitoring interval <
2-60
>
no fiber-monitoring interval
Default
The interval is set to 5 seconds by default.
Mode
Interface configuration mode for a fiber port.
Example
To set the fiber monitoring polling interval for port 1.0.2 to 30 seconds, use the
commands:
awplus(config)#
interface port1.0.2
awplus(config-if)#
fiber-monitoring interval 30
To reset the fiber monitoring polling interval back to the default (5s), use the
commands:
awplus(config)#
interface port1.0.2
awplus(config-if)#
no fiber-monitoring interval
Related
Commands
Parameter
Description
<2-60>
Optical power polling interval in seconds.