C613-50170-01 Rev B
Command Reference for x510 Series
2044
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
O
PEN
F
LOW
C
OMMANDS
OPENFLOW
INACTIVITY
openflow inactivity
Overview
Use this command to set the value of the Controller inactivity timeout.
Use the
no
variant of this command to reset the inactivity timeout value to its
default.
Syntax
openflow inactivity <
5-2073600
>
no openflow inactivity
Default
10 seconds.
Mode
Global Configuration
Usage
OpenFlow uses the inactivity probe timer to monitor its connection to
Controller(s). If no message is received from any Controller for three times the
inactivity probe interval, then OpenFlow will take over responsibility for setting up
flows, if in standalone mode.
Example
To configure the inactivity probe timeout to 20 seconds, enter the commands:
awplus#
configure terminal
awplus(config)#
openflow inactivity 20
To reset the inactivity probe timeout to its default value of 10 seconds, enter the
commands:
awplus#
configure terminal
awplus(config)#
no openflow inactivity
Related
Commands
Command
changes
Version 5.4.7-1.1: command added.
Parameter
Description
<5-2073600>
Specifies the timeout value in seconds
inactivity
OpenFlow inactivity probe