C613-50170-01 Rev B
Command Reference for x510 Series
730
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
OWER
OVER
E
THERNET
C
OMMANDS
POWER
-
INLINE
ALLOW
-
LEGACY
power-inline allow-legacy
Overview
This command enables detection of pre-IEEE 802.3af Power Ethernet standard
legacy Powered Devices (PDs).
The no variant of this command disables detection of pre-IEEE 802.3af Power
Ethernet standard legacy Powered Devices (PDs).
Syntax
power-inline allow-legacy
no power-inline allow-legacy
Default
Detection of legacy PDs is enabled on all ports
Mode
Global Configuration
Examples
To disable detection of legacy PDs, use the following commands:
awplus#
configure terminal
awplus(config)#
no power-inline allow-legacy
To enable detection of legacy PDs, use the following commands:
awplus#
configure terminal
awplus(config)#
power-inline allow-legacy
Validation
Commands
power-inline