C613-50170-01 Rev B
Command Reference for x510 Series
368
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
C
ONNECTIVITY
F
AULT
M
ANAGEMENT
C
OMMANDS
SHOW
MEP
-
ALARM
STATUS
show mep-alarm status
Overview
Use this command to show any alarms that have been declared by Local MEPs, and
the defect(s) that caused the alarm.
Syntax
show mep-alarm status
Mode
User Exec/Privileged Exec
Usage
A Local MEP is used to detect connectivity faults with other remote MEPs that are
in the same Maintenance Association (MA) and Maintenance Domain (MD) as the
Local MEP. A Local MEP looks first for connectivity defects, and if these defects
persist for a long enough period of time (typically 2.5 seconds), then an alarm is
declared.
Example
To show the alarms on local MEPs, use the command:
awplus#
show mep-alarm status
Output
Figure 9-13:
Example output from
show mep-alarm status
Related
Commands
Command
changes
Version 5.4.7-1.1: command added
awplus#show mep-alarm status
CFM Domain Name CFM Service Name MEP Active Alarm
------------------------------------------------------------------
MD-INST1 MA-INST1-1 12 someRMEPCCM
Table 9-9: Parameters in the output from
show mep-alarm status
Parameter
Description
CFM Domain Name
The domain name.
CFM Service Name
The MA name.
Active Alarms
The highest priority defect causing the alarm, one of the
following: someRDI, someMACstatus, someRMEPCCM,
errorCCM, or xconCCM.
MEP
The local MEP's ID.