C613-50170-01 Rev B
Command Reference for x510 Series
851
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
IP
V
6 C
OMMANDS
IPV
6
ND
MINIMUM
-
RA
-
INTERVAL
ipv6 nd minimum-ra-interval
Overview
Use this command in Interface Configuration mode to set a minimum Router
Advertisement (RA) interval for a VLAN interface.
Use the
no
variant of this command in Interface Configuration mode to remove the
minimum RA interval for a VLAN interface.
Syntax
ipv6 nd minimum-ra-interval <
seconds
>
no ipv6 nd minimum-ra-interval
Default
The RA interval for a VLAN interface is unset by default.
Mode
Interface Configuration for a VLAN interface.
Examples
To set the minimum RA interval for the VLAN interface
vlan2
, use the following
commands:
awplus#
configure terminal
awplus(config)#
interface vlan2
awplus(config-if)#
ipv6 nd minimum-ra-interval 60
To remove the minimum RA interval for the VLAN interface
vlan2
, use the
following commands:
awplus#
configure terminal
awplus(config)#
interface vlan2
awplus(config-if)#
no ipv6 nd minimum-ra-interval
Related
Commands
Parameter
Description
<
seconds
>
Specifies the number of seconds between IPv6 Router
Advertisements (RAs). Valid values are from 3 to 1350
seconds.