C613-50170-01 Rev B
Command Reference for x510 Series
342
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
C
ONNECTIVITY
F
AULT
M
ANAGEMENT
C
OMMANDS
MEP
CROSSCHECK
in an MD/MA that is not subject to topology loops. A Down MP can be VLAN
aware or link-local.
An MEP can be either Up or Down for a given MD/MA, but within a bridge for the
same MD/MA, there can only be one Up or Down MEP (not both). An Up MEP must
be VLAN aware. A Down MEP may be VLAN aware. Otherwise, a Down MEP is
allowed to be link local (VLAN unaware), and its scope is that of the entire link.
Example
To create a remote MEP instance named “MA-INST2-1” with an MEP ID of 21, use
the command:
awplus(config-ether-cfm)#
mep crosscheck mpid 21 ma-name
MA-INST2-1
To destroy the remote MEP instance named “MA-INST2-1” with the MEP ID of 21,
use the command:
awplus(config-ether-cfm)#
no mep crosscheck mpid 21 ma-name
MA-INST2-1
Related
Commands
show ethernet cfm maintenance-points remote mep
Command
changes
Version 5.4.7-1.1: command added