C613-50170-01 Rev B
Command Reference for x510 Series
362
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
C
ONNECTIVITY
F
AULT
M
ANAGEMENT
C
OMMANDS
SHOW
ETHERNET
CFM
MAINTENANCE
-
POINTS
REMOTE
MEP
show ethernet cfm maintenance-points
remote mep
Overview
Use this command to show one or more Ethernet CFM maintenance points,
namely Remote Maintenance End Points (MEPs) within a given Maintenance
Association (MA) and its associated Maintenance Domain (MD), and their
configuration and status in summary format. Options include the ability to show
an individual Remote MEP in detail.
Syntax
show ethernet cfm maintenance-points remote mep domain
<
domain-name
> service <
ma-name
> [{mac <
rmep-mac-address
>|rmep
<
mep-id
>} details]
Mode
User Exec/Privileged Exec
Example
To show all the remote MEP(s)'s status for this MA and MD in summary form, use
the command:
awplus#
show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1
To show a specific remote MEP by its ID in detail, use the command:
awplus#
show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1 rmep 21 details
To show a specific remote MEP by its MAC address in detail, use the command:
awplus#
show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1 mac 000c.2526.95bf details
Parameter
Description
domain
Specify the Maintenance Domain that Remote MEP(s) are to
be shown for.
<domain-name>
Specify the Maintenance Domain's CLI instance name.
service
Specify the Maintenance Association that the Remote
MEP(s) are to be shown for.
<ma-name>
Specify the service's (Maintenance Association (MA)) CLI
instance name.
mac
Specify the remote MEP of interest by its MAC address.
<rmep-mac-address>
Specify the value of the remote MEP's MAC address using
the format HHHH.HHHH.HHHH where H is a hexadecimal
digit.
rmep
Specify the remote MEP of interest by its ID.
<mep-id>
Specify the value of the remote MEP's ID in the range 1 to
8191.