C613-50170-01 Rev B
Command Reference for x510 Series
308
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
LUGGABLES
AND
C
ABLING
C
OMMANDS
FIBER
-
MONITORING
SENSITIVITY
fiber-monitoring sensitivity
Overview
Use this command to configure the sensitivity of the alarm thresholds on the port
for active fiber monitoring.
Use the
no
variant of this command to reset the sensitivity to the default.
Syntax
fiber-monitoring sensitivity (low|medium|high|highest|fixed
<
25-65535
>)|relative <
0.01-10.0
>
no fiber-monitoring sensitivity
Default
The default is medium sensitivity.
Mode
User Exec/Privileged Exec
Usage
A log message is generated and configured actions are taken if the received optical
power drops below the baseline value by the sensitivity configured with this
command.
The sensitivity can be configured to one of four pre-defined levels in decibels or to
a fixed absolute delta in units of 0.0001mW. The alarm thresholds can be seen in
the
show system fiber-monitoring
output. The maximum absolute sensitivity
configurable is 0.0025 mW. Note that 0.0025 mW equates to a reduction of
approximately 1dB at the maximum attenuation of an AT-SPLX10/1.
Example
To set the fiber monitoring sensitivity for port 1.0.2 to a relative sensitivity of 0.1 dB,
use the commands:
awplus(config)#
interface port1.0.2
awplus(config-if)#
fiber-monitoring sensitivity relative 0.1
To reset the fiber monitoring sensitivity to the default (medium), use the
commands:
awplus(config)#
interface port1.0.2
awplus(config-if)#
no fiber-monitoring sensitivity
Parameter
Description
low
Low sensitivity (+/-2 dB)
medium
Medium sensitivity (1 dB) (default)
high
High sensitivity (the greater of 0.5 dB and 0.0025 mW)
high
est
The highest sensitivity available: 0.0025mW
fixed
<
25-65535
>
Fixed sensitivity at the specified level in 0.0001 mW.
relative
<
0.01-10.0
>
Relative sensitivity at the specified level in dB.