DC Modular
EN
Installa on details
NL
Installa edetails
Smart terminal design allows dual mirrored cable lug connec ons.
5 wire interface cable for external control by panel switch, ba ery monitor or BMS. Compa ble with
two wire or single wire On/Off control. Includes status wire for controlling indicator light or providing
feedback to BMS.
Special fiber reinforced plas c housing offers excellent high temperature proper es, good chemical
resistance and high strength.
Robust transparent covers with breakouts to allow wire access from any direc on.
Local Open and Close bu ons on top, to manually override the switch state.
Stainless steel studs, washers and nuts for op mal corrosion resistance.
Smart high current magne c latching relay, draws virtually no current in On (Close) or Off (Open)
state.
Silver alloy contacts and silver plated copper busbars, for maximum conduc vity and high reliability
when switching live loads.
Unique grid op mized footprint allows space saving arrangements with other DC Modular products.
General opera on |
Algemene werking
RBS features
Precau ons
Please install this product in a dry indoor loca on, as close as possible to the ba ery. To be installed
only by qualified technicians.
To avoid fire hazards, use correctly sized cables which are suitable to carry the expected load currents
in your applica on. The maximum con nuous RBS current ra ng of 500A is only valid when a total
cable size of at least 200mm² is connected to the M10 studs. Or when the RBS is part of a DC Modular
system containing large busbars and fuseholders.
To avoid fire hazards or damaging the RBS, please make sure that all nuts are securely ghtened.
Please apply our recommended torque ra ng of 22Nm for the M10 nuts.
To avoid fire hazards or damaging the RBS, please make sure that spring- and flat washers are always
placed directly below the nut. Never place washers between: busbar and cable lug, mul ple cable lugs
on the same stud, busbar and linkplate or cable lug and linkplate.
Please make sure that all connec on cables are properly strain relieved, to avoid excessive mechanical
stress on the RBS.
Voorzorgsmaatregelen
Installeer dit product alleen in een droge omgeving, zo dicht mogelijk bij de accu. Installa e enkel te
verrichten door een gekwalificeerd installateur.
Gebruik om brandgevaar te voorkomen alleen correct gedimensioneerde kabels, geschikt voor de te
verwachten stromen. De maximale RBS stroom van 500A, is alleen geldig wanneer de kabels op de
M10 terminals een kwadratuur van minimaal 200mm² hebben. Of wanneer de RBS onderdeel is van
een DC Modular systeem, er grote busbars en/of zekeringhouders mee in verbinding staan.
Om brandgevaar te voorkomen, dient u er voor te zorgen dat alle moeren voldoende worden
aangedraaid. Raadpleeg hiervoor ons aanbevolen aandraaimoment van 22Nm voor de M10 moeren.
Om schade aan de RBS of brandgevaar te voorkomen, dienen de veerring en de vlakke ring zich al jd
direct onder de moer te bevinden. Plaats ringen nooit tussen: busbar en krimpoog, meerdere
krimpogen op dezelfde bout, busbar en verbindingsplaat of krimpoog en verbindingsplaat.
Zorg voor voldoende trekontlas ng op alle kabels. Dit om een te hoge mechanische belas ng op de
RBS te voorkomen.
Contacten van een zilver legering en verzilverde koperen aansluitplaten zorgen voor de beste geleiding
en een hoge betrouwbaarheid bij het schakelen van belas ngen.
Slim bistabiel relais voor het schakelen van hoge stromen, verbruikt zelf vrijwel geen stroom in de ‘aan’
(gesloten) of ‘uit’ (geopende) stand.
Lokale ‘Open’ en ‘Close’ knoppen kunnen de controle van het hoofdcontact overnemen.
5-draads aansluitkabel voor externe besturing vanuit een paneel schakelaar, ba erij monitor of BMS.
Geschikt voor 2-draads en enkeldraads besturing van het hoofdcontact. Inclusief status draad voor
sturing van indicator of terugkoppeling naar BMS.
Op male corrosiebestendigheid door gebruik van RVS bouten, ringen en moeren.
Unieke raster gebaseerde basisafme ngen staan zeer compacte forma es van meerdere DC Modular
producten toe.
Speciale vezel versterkte kunststof behuizing biedt uitstekende hoge temperatuur eigenschappen,
goede bestendigheid tegen chemische stoffen en een zeer hoge sterkte.
Transparante afdekkappen met uitbreekbare kanten voor kabelverbindingen vanuit meerdere hoeken.
Door een slim aansluitklem ontwerp kunnen twee krimpogen ook gespiegeld worden gemonteerd.
RBS eigenschappen
500A Remote Ba ery Switch (RBS)
500A Extern gestuurde accuschakelaar (RBS)
EN
NL
1
2
3
4
5
1
2
3
4
5
!
!
TBS Electronics BV | De Marowijne 3 | 1689AR Zwaag | The Netherlands | www.tbs-electronics.com
TBS RBS Manual Rev3endf
RBS specifica ons
Parameter
DCM-RBS-12-500
(art# 5074510)
(art# 5074520)
DCM-RBS-24-500
Contact circuit (electrical)
Rated voltage
60Vdc
Nominal current @ 25°C
500A (see Precau on #2)
Cranking current (1 minute)
1000A
Nominal make / break current
500A (0 .. 34Vdc)
350A (35 .. 60Vdc)
Peak make / break current
1600A (0 .. 34Vdc)
1200A (35 .. 60Vdc)
Control circuit (electrical)
Coil / supply voltage (+Vdc)
7 .. 17Vdc
14 .. 34Vdc
Coil / supply current (idle state)
< 100
μ
A
Coil / supply current (state change)
< 4A
< 3A
General
Remote control ¹⁾
By control wires (length 40cm, max. 15m)
Local control
On/Standby, Close contact, Open contact
Indicators
Contact open, Contact close, Error and Setup
Protected against
High temperature, High/Low supply voltage,
Igni on (ISO 8846)
Mechanical life
100000 cycles
Electrical life
10000 cycles (@ 400A/24V/resis ve)
Opera ng temperature range
-20 .. +60°C
Connec on studs / DCM grid size
M10 / 1 x 3
Protec on class / weight
IP 65 / 800 grams
Standards
EMC: 2014/30/EU, Low voltage direc ve: 2014/35/EU,
RoHS: 2011/65/EU, Automo ve: EN 50498, ISO 8846
0
I
OPEN
CLOSE
(2 sec)
Open contact
Open contact
Close contact
Sluit contact
Power bu on. Press 2 seconds to turn the RBS
on or off. When turned off, the RBS will
automa cally open the contact. In off mode, the
RBS will ignore any control wire commands.
Aan/uit knop. Druk 2 seconden om de RBS in- of
uit te schakelen. Wanneer deze wordt uitgeschakeld,
zal het contact automa sch geopend worden. In de
uit stand zullen alle stuurkabel commando’s
genegeerd worden.
Green flash - contact open
Red flash - error mode
Groen knipperend - contact open
Rood knipperend - foutmodus
Green flash - contact closed
Red flash - error mode
Groen knipperend - contact gesloten
Rood knipperend - foutmodus
Change control mode |
Wijzig stuurmodus
When in off mode, press all three bu ons simultaneously for three seconds to enter the setup mode:
Vanuit de uit-stand alle drie knoppen tegelijk ingedrukt houden voor drie seconden om de setup
modus te ac veren:
RBS specifica es
Parameter
(art# 5074510)
DCM-RBS-12-500
(art# 5074520)
DCM-RBS-24-500
Contact circuit (elektrisch)
Maximale spanning
60Vdc
Max. con nustroom @ 25°C
500A (zie voorzorgsmaatregel #2)
Aanloopstroom (1 minuut)
1000A
Nominale maak- / verbreekstroom
350A (35 .. 60Vdc)
500A (0 .. 34Vdc)
Piek maak- / verbreekstroom
1600A (0 .. 34Vdc)
1200A (35 .. 60Vdc)
Besturingscircuit (elektrisch)
Spoel / voedingsspanning (+Vdc)
7 .. 17Vdc
14 .. 34Vdc
Spoel / voedingsstroom (rust)
< 100
μ
A
Spoel / voedingsstroom (schakelen)
< 4A
< 3A
Algemeen
Bediening op afstand ¹⁾
Via besturingsbedrading (lengte 40cm, max. 15m)
Bediening lokaal
Aan/Standby, Sluit contact, Open contact
Indicatoren
Contact open, Contact gesloten, Fout en Instelmodus
Beveiligd tegen
Hoge temperatuur, Hoge/lage voedingsspanning,
ontsteking (ISO 8846)
Mechanische levensduur
100000 cycli
Elektrische levensduur
10000 cycli (@ 400A/24V/resis ve)
Werkingstemperatuur (omgeving)
-20 .. +60°C
Verbindingsbouten / rastermaat
M10 / 1 x 3
Beschermingsklasse / Gewicht
IP 65 / 800 gram
Normen
EMC: 2014/30/EU, Low voltage direc ve: 2014/35/EU,
RoHS: 2011/65/EU, Automo ve: EN 50498, ISO 8846
50.0mm
150.0mm
64.5mm
94.0mm
38.0mm
138.0mm
Dimensions |
Afme ngen
Nut |
Moer
Spring washer |
Veerring
Washer |
Ring
Cable lugs |
Krimpogen
Assembly sequence:
Assemblage volgorde:
0
I
O
P
E
N
C
L
O
S
E
(2 sec)
Battery |
Accu
Ground
Massa
Fuseholder
Zekeringhouder
Busbar
Busbar
5A - 8A fuse
5
A
- 8A zekering
1A fuse
1A zekering
R
ed |
R
ood
Black |
Zwart
Close
Sluiten
Open
Openen
Br
own |
Bruin
Or
ang
e |
Oranje
External momentary switch
(TBS art.no. 5095000-1)
Externe momentschakelaar
(TBS art.nr. 5095000-1)
Yellow |
Geel
R
Wire |
Draad
Standard func on |
Standaard func e
Red |
Rood
+Vdc con nuous supply |
+Vdc con nue voeding
Black |
Zwart
Ground |
Massa
Brown |
Bruin
+Vdc pulse closes contact |
+Vdc puls sluit contact
Orange |
Oranje
+Vdc pulse opens contact |
+Vdc puls opent contact
Yellow |
Geel
¹⁾
Status (LED) output |
Status (LED) uitgang
¹⁾
¹⁾ The Status output is a ground referenced open collector port with a
maximum switching capacity of 34V / 100mA (Rout ≈ 10
Ω
)
¹⁾ De Status uitgang is een aan massa gerefereerde open collector poort met
een maximale schakelcapaciteit van 34V / 100mA (Ruit ≈ 10
Ω
)
Wiring example |
Bedradingsvoorbeeld
Error table (both LEDs flashing red)
Fou abel (beide LEDs knipperen rood)
Cause |
Oorzaak
Remedy |
Remedie
Supply voltage too low
Voedingsspanning te laag
Increase supply voltage
Verhoog voedingsspanning
Supply voltage too high
Voedingsspanning te hoog
Decrease supply voltage
Verlaag voedingsspanning
RBS Temperature too high
RBS temperatuur te hoog
Reduce the contact current, check all
cable connec ons
controleer alle kabelverbindingen
Reduceer de stroom door het contact,
Contacts are welded
Contacten zijn verkleefd
Vervang de RBS
Replace the RBS
Error table |
Fou abel
R = 5mm (x4)
¹⁾ Panel switch with LED indicator op onally available (Art. no. 5095000-1)
¹⁾ Paneelschakelaar met LED indicator op oneel beschikbaar (Art. nr. 5095000-1)
8
7
3
1
2
0
OPEN
I
CLOSE
+
+
(3 sec)
Control mode table |
Stuurmodus tabel
Modus nr.
Mode no.
Open LED
Open LED
Close LED
Close LED
Control mode
Control modus
1
2-draads, geen contact wijziging bij opstarten
2-wire, no contact change at power-up
2
2-draads, contact sluit bij opstarten
2-wire, contact closes at power-up
3
2-wire, contact opens at power-up
2-draads, contact opent bij opstarten
4
single-wire, normally open contact
enkeldraads, normaal geopend contact
5
single-wire, normally closed contact
enkeldraads, normaal geloten contact
G
O
G
G
O
O
O
O
G
=
=
=
LED off
LED uit
LED green
LED groen
LED orange
LED oranje
Step through the control modes by pressing the OPEN (up) or CLOSE (down) bu ons
Stap door de controlmodus op es m.b.v. de OPEN (omhoog) of CLOSE (omlaag) knoppen
+Vdc pulse on brown wire to close, +Vdc pulse on orange wire to open.
+Vdc puls op bruine draad voor sluiten, +Vdc puls op oranje draad voor openen.
Modes 1, 2 & 3:
When the desired control mode is selected, press the Power bu on for 2 seconds to save the se ng.
Press the Power bu on again for 2 seconds to ac vate the RBS with the new control mode.
Wanneer de gewenste controlmodus geselecteerd is, druk op de aan/uit knop voor 2 seconden om de
instelling op te slaan. Druk wederom 2 seconden op de aan/uit knop om de RBS te ac veren met de
nieuwe controlmodus.
+Vdc con nuous on brown wire to close, 0Vdc on brown wire to open. Orange wire
not used.
+Vdc con nu op bruine draad voor sluiten, 0Vdc op bruine draad voor openen.
Oranje draad niet gebruikt.
Mode 4:
+Vdc con nuous on brown wire to open, 0Vdc on brown wire to close. Orange wire
not used.
+Vdc con nu op bruine draad voor openen, 0Vdc op bruine draad voor sluiten.
Oranje draad niet gebruikt.
Mode 5:
Main cable installa on |
Hoofdkabel installa e