background image

A51606-SW 48-Port SAS Switch

 

 

 
 QUICK SAS SWITCH INSTALLATION 
 

To install the 

A51606-SW

 SAS Switch, follow these steps: 

 

1. 

Unpack the Switch and inspect it for damage. Place the shipping carton on a grounded surface before removing the Switch 

from the carton. 

 
2. 

Place the Switch in a location that ensures adequate open space behind the fans and in front of the air intakes. 

 

WARNING:

 

To prevent the Switch from overheating, do not operate it in an environment that exceeds the maximum 
recommended ambient temperature of 45°C (113°F). 

 
3. 

Attach the power cords to the power inputs by pushing firmly all the way in on the fan side of the Switch. Plug the other end of 

the power cord into the main power source.  
 

WARNING:

 

Provide the Switch with a proper AC-protective earth ground connection. Never defeat the ground 
conductor or operate the Switch in the absence of a suitably installed ground conductor. 

 
4

. Check that 

Java

 

8 update 40

 or later is installed on the host system that will run the 

SAS Domain Manager Utility.

 

 
5. 

The 10/100 Ethernet connector (RJ-45 connector) on the SAS connector side of the Switch provides access to the SDM 

Domain Manager utility.  Use this utility to configure and manage the Switch. 
 
- Use a standard RJ-45 cable, if connecting to an external Ethernet hub or Switch. 

 
6. 

Plug the other end of the RJ-45 cable into an Ethernet hub/Switch or a computer.  

Start the SDM_GUI.jar utility not the 

imbedded version.

 

 

WARNING:

 Do not use

 the imbedded SDM that uses a web browser , it is out dated. 

 
7. 

Connect the Switch to your hardware configuration. 

 
Refer to the 

A51606-SW SAS Switch User Guide 

provided on the documentation CD for examples of hardware configurations 

and for the types of connectors and cables needed. 
 

 
SWITCH DEFAULTS 
 

Parameter 

Value 

 

IP Address 

192.168.1.100 

 

Subnet Mask 

255.255.255.0 

 

Gateway Address 

192.168.1.1 

 

DHCP 

disabled 

 

Warning Temperture Limit 

70

°C

 

 

Critical Temperature Limit 

80

°C

 

Maximum allowable temperature is 80

°C

 

Warning Fan Limit 

10,000 rpm 

 

Critical Fan Limit 

5,000 rpm 

 

User 

admin 

 

Password 

admin 

 

Zoning password 

 

Password is “blank” 

WWN 

 

On the label on the back 

 
 

Отзывы: