F26.07
Brake open frequency (down) 0.00 〜10.00Hz
1.00Hz
●
F26.08
Brake close frequency (down) 0.00 〜10.00Hz
0.20Hz
●
F26.09
Brake open current
0.0 〜100.0%
40.00%
●
F26.10
Brake open frequency hold
time
0.00〜10.00s
0.30s
●
F26.11
Brake open type
0: open according to
frequency;
1:opene according to
frequency and current
0
●
F26.12
Emergency operation
frequency
0.00〜50.00Hz
8.00Hz
●
F26.13
Overhaul running frequency
0.00〜50.00Hz
8.00Hz
●
F26.14
Emergency signal processing
0: Elevator does not run;
1: UPS power supply
operation
0
●
F26.15
Running contactor closing
delay
0.00~10.00s
0.20s
●
F26.16
Running contactor opening
delay
0.00~10.00s
0.10s
●
F26.17
Brake closed frequency hold
time
0.00~10.00s
0.50s
●
F26.18
Short floor function mode
0: invalid
1: valid
0
F26.19
Short floor function setting
speed
0.00Hz~P0-03
(maximum frequency)
30.00Hz
●
F26.20
Increasing frequency of
electric mode
0.00〜3.00Hz
0.00Hz
●
F26.21
Decreasing frequency of
power generation mode
0.00〜3.00Hz
0.00Hz
●
F26.22
Emergency signal effective
time
0.0〜500.0s
10.0s
●
F26.23
Emergency signal invalid time 0.0〜1000.0s
180.0s
●
-216-
-290-
Function
code
Name
Description
(setting range)
Factory
Default
Change
C
h
a
p
te
r
1
0
Chapter 10 Appendix
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......