Step 7:
set the acceleration and deceleration should be F05.05=0 P0-12/F0-13/
F09.00 / F09.01 /F09.02 /F09.03 / F09.04/F09.05 all set2.5.
Step 8:
F07.02= 7 when the inverter is stopped or 0Hz is running TA-TB, normally open
change into normally closed
P0-01 = 1 Terminal control
P0-06 = 6 Multi - Step Speed
P0-12 = 2.5 Acceleration time
P0-13 = 2.5 Deceleration time
F05.05 = 0 overvoltage Stall gain
F06.02 = 12 multi - function terminal 1
F06.03 = 13 multi - function terminal 2
F06.04 = 14 multi - function terminal 3
F07.02 = 7 Zero -speed ruining 2 (having output at stop)
F09.00/01/02/03/04/05 = 2.5
F12.03 = 20 % Slow Speed
F12.04= 80% /100% high speed
F12.06 =? Maintenance Speed