-158-
Value
Function
Description
22
PID invalidation (pause)
When the frequency source P0-06 is PID, the PID failure
will make the inverter maintain the current frequency
output.
23
PLC status reset
The PLC is suspended during the execution process,
and can be restored to the initial state of the simple PLC
through this terminal being valid when it is running again.
24
Swing pause
Pause the swing frequency, and the inverter outputs at
the center frequency.
25
Timer trigger input
Timer input signal, when the valid time of this signal
reaches the set closing and opening time, the timing
output function is valid. It needs to be used with Y1
output No. 17 function and P7-39, P7-40.
26
Immediate DC braking
When this terminal is valid, the inverter will DC brake
immediately, and the braking current P1-16 will be set
27
External fault normally
closed input
When the external fault signal is sent to the inverter, the
inverter will report Err28 fault and stop according to the
stop mode set by P9-23.
28
Counter input
The terminal of counting pulse input, cooperate with Pb-
08 to realize the function of setting count value
29
Counter reset
This terminal is used to clear the counter status.
30
Length count input
This terminal is used to count the length.
31
Length reset
This terminal is used to clear the length.
32
Torque control
prohibited
The AC drive is prohibited from torque control and enters
the speed control mode.
33
Pulse input (enabled
only for HDI)
It is the pulse input terminal (only valid for HDI)
34
Frequency modification
prohibited
When the terminal is active, the inverter does not
respond to frequency changes.
35
PID action direction is
reversed
When this terminal is valid, the PID action direction is
opposite to the direction set by PA-04.
36
External STOP terminal
1
When the command source P0-04 is the operation
panel, this terminal can be used to stop the inverter,
which is equivalent to the function of the STOP key on
the keyboard.
Chapter 6 Description of Function Codes
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......