Chapter 5 Function & Parameter Table
-82-
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-09
Auxiliary frequency
source Y range
0% to 100%
100%
☆
P0-10
Frequency source
selection
Ones place: frequency source selection
0: Main frequency source X
1: Main and auxiliary operation results
(the operation relationship is
determined by ten digits)
2: Switch between main frequency
source X and auxiliary frequency
source Y
3: Switch between the main frequency
source X and the main and auxiliary
operation results
4: Switch between auxiliary frequency
source Y and main and auxiliary
operation results
Tens place: main and auxiliary
operation relationship of frequency
source
0: main + auxiliary
1: Primary-Secondary
2: the maximum value of the two
3: the minimum value of the two
00
☆
P0-11
Preset frequency
0.00Hz
~
Maximum frequency P0-14
50.00Hz
☆
P0-13
Motor running
direction selection
0: Consistent with the current motor
direction
1: Opposite to the current motor
direction
2: Inversion is prohibited
0
☆
P0-14
Maximum output
frequency
When P0-20=1, the adjustable range is
50.0Hz
~
1200.0Hz;
When P0-20=2, the adjustable range is
50.00Hz
~
600.00Hz;
50.00Hz
★
P0-15
Upper limit
frequency source
0: Digital given (P0-16)
1: AI1
2: AI2
3: Communication given
4: PULSE setting
0
★
C
h
a
p
te
r
5