Chapter 6 Description of Function Codes
-226-
Function
code
Name
Description
(setting range)
Factory
Default
Change
A3-12
Torque current regulator Ki
0
~
30000
1300
☆
A3-13
Excitation current regulator Kp
0
~
30000
2000
☆
A3-14
Excitation current regulator Ki
0
~
30000
1300
☆
A3-15
Flux Brake Gain
100
~
200
110
☆
A3-16
Field weakening torque correction
factor
50%
~
150%
100%
☆
A3-17
Slip Compensation Coefficient
50%
~
200%
100%
☆
A3-18
Speed loop feedback filter time
constant
0.000s
~
1.000s
0.015s
☆
A3-19
Speed loop output filter time
constant
0.000s
~
1.000s
0.000s
☆
A3-20
Electric torque upper limit source
0~4
0
☆
A3-21
Electric torque upper limit
0.0%
~
200.0%
150.0%
☆
A3-22
Braking torque upper limit source
0~4
0
☆
A3-23
Braking torque upper limit
0.0%
~
200.0%
150%
☆
Group B0: System parameters
B0 is used to manage the inverter function code group, which can be set by the user as req-
uired.
Function
code
Name
Description
(setting range)
Factory
Default
Change
B0-00
Function code read-only selection
0~1
0
☆
0: invalid
1: Except for B0-00, all function codes can only be viewed and cannot be modified, which can
prevent the parameters from being misoperated
Function
code
Name
Description
(setting range)
Factory
Default
Change
B0-01
LCD top menu display/LED
second line display
0~5
0
☆
C
h
a
p
te
r
6