-215-
Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-38
Running time of simple PLC multi-
speed 10
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-39
Acceleration/deceleration time of
simple PLC multi-speed 10
0
~
3
0
☆
PC-40
Running time of simple PLC multi-
speed 11
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-41
Acceleration/deceleration time of
simple PLC multi-speed 11
0
~
3
0
☆
PC-42
Running time of simple PLC multi-
speed 12
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-43
Acceleration/deceleration time of
simple PLC multi-speed 12
0
~
3
0
☆
PC-44
Acceleration/deceleration time of
simple PLC multi-speed 13
0
~
3
0
☆
PC-45
Running time of simple PLC multi-
speed 14
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-46
Acceleration/deceleration time of
simple PLC multi-speed 14
0
~
3
0
☆
PC-47
Running time of simple PLC multi-
speed 15
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-48
Acceleration/deceleration time of
simple PLC multi-speed 15
0
~
3
0
☆
PC-49
Running time of simple PLC multi-
speed 15
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
PC-50
Time unit of multi-speed
0
~
1
0
☆
Define the running time of each segment of the 16-segment program and the selection of ac-
celeration speed of each segment. Among them, the selection of acceleration and decelera-
tion time 0~3 respectively represents the acceleration and deceleration time 0: P0-23, P0-24;
acceleration and deceleration time 1: P7-03, P7-04; Deceleration time 3: P7-07, P7-08.
PC-50 defines the unit of each run time of the PLC.
0: seconds;
1 hour.
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-51
Multi-speed priority mode
selection
0~1
1
☆
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......