-39-
Chapter 3 Installation
C
h
a
p
te
r
3
3.6 Control circuit terminal and wiring
3.6.1 Schematic diagram of control circuit wiring terminal
Figure 3-9
Three-phase 220V/380V below 2.2 KW
GND AO1 485- DI1
DI2
DI3
DI4 HDI5 +24V RA
RB
RC
+10V AI1
AI2 485+ CME COM
Y1
COM TA
TB
TC
FM
AO2
Figure 3-10
Three-phase 380V/660V 4.0KW or more
+10V AI1
AI2
DI1
DI2
DI3
DI4 HDI
T/A
T/B
T/C
GND GND AO1 485+ 485- CME
FM COM +24V
COM Y1
RA
RB
RC COM DI6
DI7
DI8
GND TEMP AI3 AO2 DI9 DI10
Y2
3.6.2 Control terminal function description
Sort
Terminal
Name
Function Description
Power
supply
+
10V-GND
External
+10V power
supply
P10V power supply to the outside, the
maximum output current: 10mA
Generally used as working power supply of external
potentiometer, potentiometer resistance range:
1~5k
Ω
24V-COM
External
+24V power
supply
P24V power supply to the outside, generally
used as the working power supply of digital input and
output terminals and external sensor power supply,
Maximum output current: 200mA
Summary of Contents for 2S-0.4G-B