-211-
Chapter 6 Description of Function Codes
Group PC: Multi-segment instruction and simple PLC function
The simple PLC function is that the inverter has a built-in programmable logic controller (PLC)
to complete the automatic control of multi-segment frequency logic. The running time, running
direction and running frequency can be set to meet the requirements of the process.
KD600 series intelligent inverter can realize 16-stage speed change control, and there are 4
kinds of acceleration and deceleration time for selection.
When the set PLC completes a cycle, the multi-function digital output terminal Y1, multi-
function relays RELAY1 and RELAY2 can output ON signal. For details, see P6-00~P6-02.
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-00
Multi-speed 0
-100.0%
~
100.0%
0.0%
☆
PC-01
Multi-speed 1
-100.0%
~
100.0%
0.0%
☆
PC-02
Multi-speed 2
-100.0%
~
100.0%
0.0%
☆
PC-03
Multi-speed 3
-100.0%
~
100.0%
0.0%
☆
PC-04
Multi-speed 4
-100.0%
~
100.0%
0.0%
☆
PC-05
Multi-speed 5
-100.0%
~
100.0%
0.0%
☆
PC-06
Multi-speed 6
-100.0%
~
100.0%
0.0%
☆
PC-07
Multi-speed 7
-100.0%
~
100.0%
0.0%
☆
PC-08
Multi-speed 8
-100.0%
~
100.0%
0.0%
☆
PC-09
Multi-speed 9
-100.0%
~
100.0%
0.0%
☆
PC-10
Multi-speed 10
-100.0%
~
100.0%
0.0%
☆
PC-11
Multi-speed 11
-100.0%
~
100.0%
0.0%
☆
PC-12
Multi-speed
12
-100.0%
~
100.0%
0.0%
☆
PC-13
Multi-speed 13
-100.0%
~
100.0%
0.0%
☆
PC-14
Multi-speed 14
-100.0%
~
100.0%
0.0%
☆
PC-15
Multi-speed 15
-100.0%
~
100.0%
0.0%
☆
When the frequency source selection P0-06, P0-07, P0-10 is determined as the multi-speed
running mode, it is necessary to set PC-00~PC-15 to determine its characteristics.
Description: The symbols of PC-00
~
PC-15 determine the running direction of simple PLC. If
it is a negative value, it means running in the opposite direction.
Simple PLC schematic diagram:
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......