4.13 How to use inverter serial communication
See the P8 group function for the hardware communication parameter configurati-
on of the communication port. Setting the communication rate and data format to
be consistent with the host computer is the premise for normal communication.
The serial port of KD600 has a built-in MODBUS-RTU slave communication prot-
ocol. The host computer can query or modify the inverter function code, various
running status parameters, and send running commands and operating frequenc-
ies to the inverter through the serial port.
Port
Host
computer
Rs485
485+ 485-
Communication settings should be
consistent with the host computer settings
P8-00: Communication rate
P8-01: Check
P8-02: Address
P8-03: Response delay
P8-04: Communication timeout
P8-05: Transmission Format
Run command
Running state
parameters
Function code
Figure 4-30
Communication setting diagram
The internal information of function codes, various operating status parameters,
various operating instructions and other information in KD600 is organized in the
way of "register parameter address".
For more details, please refer to Appendix A: KD600 Modbus Communication
Protocol.
4.14 Password setting
The inverter provides the user password protection function. When P7-49 is set to
non-zero, it is the user password. After returning to the status parameter interface,
the password protection will take effect. At this time, press the PRG key, it will dis
-
play "-----", only the status parameters are displayed, you must press the key on
the "-----" interface, and the panel displays "00000", after entering the user passw
-
ord correctly, you can enter the normal menu to check and set the function code,
otherwise the panel will display "-----" and the function code cannot be entered.
If you want to cancel the password protection function, you can only enter through
the password according to the above steps, and set P7-49 to 0.
C
h
a
p
te
r
4
Chapter 4 Operation and Display
-78-
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......