Chapter 5 Function & Parameter Table
-84-
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-25
Overmodulation
voltage boost value
0%
~
10%
3%
★
P0-26
Carrier frequency
0.5kHz
~
16.0kHz
Model is
determined
☆
P0-27
The carrier frequency
is adjusted with
temperature
0: Invalid;
1: Valid;
1
☆
P0-28
Parameter
initialization
0: No operation
1: Restore factory parameters,
excluding motor parameters, record
information and frequency decimal
point P0-20
2: Clear record information
3: Backup current user parameters
4: Restore user backup parameters
0
★
P0-29
LCD upload and
download parameter
selection
0: No function
1: Download parameters to LCD
2: Only upload P4 group parameters
3: Upload parameters other than
group P4
4: Upload all parameters
0
☆
Group P1: Start-stop control
P1-00
Start method
0: direct start
1: Speed Tracking
2: Asynchronous motor pre-
excitation start
0
☆
P1-01
Speed tracking
method
0: start from stop frequency
1: Start with target frequency
2: start from maximum frequency
0
★
P1-02
Maximum speed
tracking current
30%
~
150%
100%
★
P1-03
Speed tracking
speed
1
~
100
20
☆
P1-04
Start frequency
0.00Hz
~
10.00Hz
0.00Hz
☆
P1-05
Start frequency hold
time
0.0s
~
100.0s
0.0s
★
P1-06
Start DC braking
current
0%
~
100%
0%
★
C
h
a
p
te
r
5
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......