![Vicruns 2S-0.4G-B User Manual Download Page 278](http://html1.mh-extra.com/html/vicruns/2s-0-4g-b/2s-0-4g-b_user-manual_1013433278.webp)
-277-
AC drive
Power
Brake unit
Brake resistance
Model
Quantity
(piece)
Power(W)/Resistance value(
Ω)
Quantity
(piece)
380V
160KW
DBU-4160
1
30000
30
1
200KW
1
35000
25
1
220KW
DBU-4280
1
40000
20
1
250KW
1
44000
13.6
1
280KW
1
50000
25
1
315KW
1
55000
15
1
350KW
1
60000
13.6
1
400KW
1
60000
8
1
500KW
1
80000
6
1
Note:
Please select the power and the resistance value recommended by our
company.
The power and the resistance value that recommended above can be
calculated by 100% braking torque and 10% frequency of utilization.
The power and the resistance value can be appropriately reduced as
long as it meets the load demand and the system is reliable: The power
and the resistance value of the braking resistor should be appropriately
changed if the braking torque and frequency of utilization need to be
increased,or users can contact the company.
When installing a braking resistor
,
please consider the safety and the
inflammability of the surrounding environment.
The frequency of use of Braking:
UD= t1/ t2*100%
tl
:
the braking time in a working period;
t2
:
a working period;
If the braking efficiency is double, the power of the corresponding braking unit
and braking resistor also need to be double.
C
h
a
p
te
r
1
0
Chapter 10 Appendix
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......