Chapter 6 Description of Function Codes
Group P4: First motor parameter
Tip:
Before tuning, you must set the correct motor rated parameters (P4-01
~
P4-06)
0: No operation, that is, tuning is prohibited.
1: Static tuning, suitable for occasions where the motor and the load are not easily disconne-
cted and cannot be rotated for tuning.
Action description: Set the function code to 1 and press the RUN key to confirm, the inverter
will perform static tuning.
2: Rotary tuning
In order to ensure the dynamic control performance of the inverter, please select rotary tunin-
g. During rotary tuning, the motor must be disconnected from the load (no load).
After selecting rotary tuning, the inverter will perform static tuning first. After the static tuning
is completed, the motor will follow the acceleration set by P4-12.
Accelerate to 80% of the rated frequency of the motor, keep it for a period of time, and then
decelerate to zero speed according to the deceleration set by P4-13, and the rotation tuning
is over.
Action description: Set the function code to 2, and press the RUN key to confirm, the inverter
will perform rotary tuning.
Tuning operation instructions:
When P4-00 is set to 1 or 2 and then press the ENTER key, “TUNE” will be displayed and
flashing at this time, then press the RUN key to start parameter tuning, and the displayed
“TUNE” will stop flashing. When the tuning is completed, the display returns to the stop state
interface. During the tuning process, you can press the STOP key to abort the tuning.
When the tuning is completed, the value of P4-00 automatically returns to 0.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P4-00
Motor parameter tuning
0
~
2
0
☆
Function
code
Name
Description
(setting range)
Factory
Default
Change
P4-01
Motor 1 rated power
0.1kw
~
1000.0kw
Model is
determined
★
P4-02
Motor 1 rated voltage
1V
~
1500V
380V
★
P4-03
Motor 1 Number of motor poles
2 to 64
Model is
determined
○
P4-04
Motor 1 rated current
0.1A
~
6000.0A<1>
P4-01 OK
★
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......