-155-
Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
P4-12
Acceleration at Dynamic Full
Tuning
1.0s
~
6000.0s
10.0s
☆
P4-13
Deceleration at dynamic full tuning 1.0s
~
6000.0s
10.0s
☆
The above function code is the acceleration and deceleration time when the motor is fully tu-
ned, and the user can reasonably set this parameter according to the actual situation of the
motor.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P4-17
Synchronous motor stator
resistance
0.001
Ω~
65.535
Ω
Model is
determined
★
P4-18
Synchronous motor D-axis
inductance
0.01Mh
~
655.35Mh
Model is
determined
★
P4-19
Synchronous motor Q-axis
inductance
0.01Mh
~
655.35Mh
Model is
determined
★
P4-20
Synchronous motor back EMF
1V
~
65535V
Model is
determined
★
P4-21
No-load current of synchronous
motor
0.0%
~
50.0%
10.0%
★