Chapter 6 Description of Function Codes
-190-
Group P8: Communication parameters
Baud rate settings:
0: 300BPS
1: 600BPS
2: 1200BPS
3: 2400BPS
4: 4800BPS
5: 9600BPS
6: 19200BPS
7: 38400BPS
The baud rate is the data transmission rate between the host computer and the inverter. The
higher the baud rate, the faster the communication speed.
Data Format:
0: No checksum: Data format <8,N,2>
1: Even parity: data format <8,E,1>
2: Odd parity: data format <8,O,1>
3: No check 1: Data format <8,N,1>
Note that the baud rate and data format set by the host computer and the inverter must be
consistent, otherwise, the communication cannot be carried out.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P8-00
Baud rate setting
0~7
5
☆
P8-01
Data Format
0.0s
~
3000.0s
0
☆
Function
code
Name
Description
(setting range)
Factory
Default
Change
P8-02
Mailing address
0
~
247
1
☆
When the local address is set to 0, that is, the broadcast address, which realizes the broad-
cast function of the upper computer.
Note:
The address of this machine is unique (except for broadcasting), which is the basic condition
for realizing point-to-point communication between the host computer and the inverter.
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......