![Vicruns 2S-0.4G-B User Manual Download Page 90](http://html1.mh-extra.com/html/vicruns/2s-0-4g-b/2s-0-4g-b_user-manual_1013433090.webp)
-89-
Chapter 5 Function & Parameter Table
Function
code
Name
Description
(setting range)
Factory
Default
Change
P4-01
Motor 1 rated power
0.1kw
~
1000.0kw
Model is
determined
★
P4-02
Motor 1 rated voltage
1V
~
1500V
380V
★
P4-03
Motor 1 Number of motor
poles
2 to 64
Model is
determined
○
P4-04
Motor 1 rated current
0.01A
~
600.00A(Motor
rated power<=30.0KW)
0.1A
~
6000.0A(Motor rated
power>30.0KW)
P4-01 OK
★
P4-05
Motor 1 rated frequency
0.01Hz
~
P0-14
50.00 Hz
★
P4-06
Motor 1 rated speed
1rpm
~
60000rpm
P4-01 OK
★
P4-07
Motor 1 no-load current
0.01A
~
P4-04 (Motor rated
power<=30.0KW)
0.1A
~
P4-04 (Motor rated
power>30.0KW)
Model is
determined
★
P4-08
Motor 1 stator resistance
0.001
Ω~
65.535
Ω
Model is
determined
★
P4-09
Motor 1 rotor resistance
0.001
Ω~
65.535
Ω
Model is
determined
★
P4-10
Motor 1 mutual inductance
0.1Mh
~
6553.5Mh
Model is
determined
★
P4-11
Motor 1 leakage inductance
0.01Mh
~
655.35Mh
Model is
determined
★
P4-12
Acceleration at Dynamic Full
Tuning
1.0s
~
6000.0s
10.0s
☆
P4-13
Deceleration at dynamic full
tuning
1.0s
~
6000.0s
10.0s
☆
P4-17
Synchronous motor stator
resistance
0.001
Ω~
65.535
Ω
Model is
determined
★
P4-18
Synchronous motor D-axis
inductance
0.01Mh
~
655.35Mh
Model is
determined
★
P4-19
Synchronous motor Q-axis
inductance
0.01Mh
~
655.35Mh
Model is
determined
★
P4-20
Synchronous motor back
EMF
1V
~
65535V
Model is
determined
★
P4-21
No-load current of
synchronous motor
0.0%
~
50.0%
10.0%
★
C
h
a
p
te
r
5
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......