Group P5: Vector control parameters
KD600 series inverters come standard with 7 multi-function digital input terminals (among
which HDI can be used as high-speed pulse input terminal) and 2 analog input terminals.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P5-00
DI1 terminal function
0
~
53
1
★
P5-01
DI2 terminal function
0
~
53
2
★
P5-02
DI3 terminal function
0
~
53
9
★
P5-03
DI4 terminal function
0
~
53
12
★
P5-04
DI5 terminal function
0
~
53
13
★
P5-05
DI6 terminal function
0
~
53
0
★
P5-06
DI7 terminal function
0
~
53
0
★
-156-
Chapter 6 Description of Function Codes
This parameter is used to set the function corresponding to the digital multi-function input
terminal. The specific function is shown in the attached table 6-1.
Value
Function
Description
0
No function
Set 0 for reserved terminals to avoid malfunction.
1
Forward RUN (FWD) The terminal is used to control forward or reverse RUN of
the AC drive.
2
Reverse RUN (REV)
3
3-wire operation
control
The terminal determines three-line control of the AC drive.
For details, see the description of F06.13.
4
Forward jog
Forward jog indicates forward JOG running, while reverse
jog indicates reverse JOG running. The JOG frequency,
acceleration time and deceleration time are described
respectively in F09.06, F09.07 and F09.08.
5
Reverse jog
6
Terminal UP
When this function takes effect, the frequency increasing
command and decreasing command will be modified
when the frequency is given by the external terminal.
When the frequency source is set to digital setting, the set
frequency can be adjusted up and down. Up/Down
change rate is set by P5-12
7
Terminal DOWN
Table 6-1 DI terminal function description
C
h
a
p
te
r
6