Value
Function
Description
25
Downloading
When the inverter is in the state of off-load, the ON signal
is output.
26
The cumulative
power-on time arrives
When the accumulative power-on time (P7-33) of the
inverter exceeds the power-on arrival time set by P7-51, it
will output ON signal.
27
The running time has
arrived
When the timing function selection (P7-36) is valid, the
inverter will output ON signal after the current running
time reaches the set timing time (P7-38).
28
Reserved
Reserved
29
Set count value
reached
When the count value reaches the value set by Pb-08, the
ON signal is output.
30
The specified count
value is reached
When the detected actual length count value reaches the
length count value set by Pb-09, the ON signal is output.
31
Motor 1, Motor 2
indication
When the current motor is No. 2 motor, the ON signal is
output.
32
Brake control output
When the holding brake is valid, the ON signal will be
output. For details, please refer to the settings in Group
B5.
33
Running at zero
speed 2
When the output frequency of the inverter is 0, the ON
signal is output. This signal is also ON in stop state.
34
Frequency level
detection PDT2 arrival
Please refer to the description of function codes P7-55
and P7-56.
35
Zero current state
Please refer to the description of function codes P7-59
and P7-60.
36
Software current
overrun
Please refer to the description of function codes P7-61
and P7-62.
37
When the lower limit
frequency is reached,
it will also output
when it stops
When the running frequency reaches the lower limit
frequency, the ON signal is output. This signal is also ON
in the stop state.
38
Alarm output
When a fault occurs in the inverter, and the processing
mode of the fault is to continue running, the inverter will
output an alarm.
39
Reserved
Reserved
40
Al1 input overrun
When the value of analog input AI1 is less than P7-67
(AI1 input protection lower limit) or greater than P7-68
(AI1 input protection upper limit), the ON signal is output.
-170-
Chapter 6 Description of Function Codes
C
h
a
p
te
r
6