Chapter 5 Function & Parameter Table
-90-
Function
code
Name
Description
(setting range)
Factory
Default
Change
Group P5: Input terminal
P5-00
DI1
terminal
function
0: No function
1: Forward rotation (FWD)
2: Reverse operation (REV)
3: Three-wire running control
4: Forward jog (FJOG)
5: Reverse Jog (RJOG)
6: Terminal UP
7: Terminal DOWN
8: Free parking
9: Fault reset (RESET)
10: run pause
11: External fault normally open input
12: Multi-segment command terminal 1
13: Multi-segment command terminal 2
14: Multi-segment command terminal 3
15: Multi-segment command terminal 4
16: Acceleration and deceleration selection
terminal 1
17: Acceleration and deceleration selection
terminal 2
18: Frequency source switching
19: UP/DOWN setting clear (terminal, keyboard)
20: Running command switching terminal
21: Acceleration and deceleration prohibition
22: PID invalid (pause)
23: PLC status reset
24: Swing frequency pause
25: Timing trigger input
26: Immediate DC braking
27: External fault normally closed input
28: Counter input
29: Counter reset
30: Length count input
31: Length count reset
32: Torque control prohibited
33: PULSE (pulse) frequency input
34: Frequency modification prohibited
35: PID action direction is reversed
36: External parking terminal 1
1
★
P5-01
DI2
terminal
function
2
★
P5-02
DI3
terminal
function
9
★
P5-03
DI4
terminal
function
12
★
P5-04
DI5
terminal
function
13
★
P5-05
DI6
terminal
function
13
★
P5-06
DI7
terminal
function
13
★
C
h
a
p
te
r
5