-165-
Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
P5-20
AI2 minimum input value
0.00V
~
10.00V
0.00V
☆
P5-21
AI2minimum input corresponding
setting
-
100.0%
~
100.0%
0.0%
☆
P5-22
AI2 maximum input value
0.00V
~
10.00V
10.00V
☆
P5-23
AI2 maximum input corresponding
setting
-
100.0%
~
100.0%
100.0%
☆
P5-24
AI2 input filter time
0.00s
~
10.00s
0.10s
☆
Same as AI1.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P5-30
PULSE (pulse) input minimum
frequency
0.00KHz
~
50.00KHz
0.00KHz
☆
P5-31
PULSE (pulse) input minimum
frequency corresponding setting
-100.0%
~
100.0%
0.0%
☆
P5-32
PULSE (pulse) input maximum
frequency
0.00KHz
~
50.00KHz
50.00KHz
☆
P5-33
PULSE (pulse) input maximum
frequency corresponding setting
-100.0%
~
100.0%
100.0%
☆
PULSE input quantization is similar to analog input quantization.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P5-35
DI1 turn-on delay time
0.0s
~
3600.0s
0.0s
☆
P5-36
DI1 off delay time
0.0s
~
3600.0s
0.0s
☆
P5-37
DI2 turn-on delay time
0.0s
~
3600.0s
0.0s
☆
P5-38
DI2 off delay time
0.0s
~
3600.0s
0.0s
☆
P5-39
DI3 turn-on delay time
0.0s
~
3600.0s
0.0s
☆
P5-40
DI3 off delay time
0.0s
~
3600.0s
0.0s
☆
It is used to set the delay time for the inverter to change the state of the DI terminal.
Currently, only DI1, DI2, and DI3 have the function of setting the delay time.
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......