Built-in Emergency leveling mode
In the using of eleva tor, if the power is cut suddenly, passengers may be kept in the cage.I-
nverters can support emergency UPS power running, Both the main circuit and the working
are powered by 220V UPS.
-216-
-288-
1AC/3AC
Power supply
MCCB
Elevator
Controller
2. Functional group
Function
code
Name
Description
(setting range)
Factory
Default
Change
F0 Group
P0-00
Speed control mode
0: No-PG vector control (SVC
)
1: PG vector control
(
FVC
)
2: V/F control
2
●
P0-01
Running command
channel
0:keypad control
1:terminal control
2:RS485 communication control
0
※
P0-06
Frequency command
selection
0: Keyboard setting, and the inverter
power-down does not remember
1: Keyboard setting, and inverter
power-off memory
2: Analog AI1 setting
3: Analog AI2 setting
4 : Analog AI3 setting
5: PULSE
pulse setting (HDI)
0
●
C
h
a
p
te
r
1
0