Chapter 6 Description of Function Codes
-147-
3: Multi-segment instruction;
4: Simple PLC;
5: PID
6: Communication given
7: PULSE pulse setting (Di5)
100.0% corresponds to the rated voltage of the motor.
;
;
;
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-16
V/F separation output voltage
digital setting
0V
~
Motor rated
voltage
0V
☆
This parameter is used to set the voltage output value when the V/F separation voltage is set
and the voltage source is the digital setting value.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-17
V/F separation output voltage
acceleration time
0.0
~
3000.0s
1.0s
☆
This parameter is used to set the acceleration time of voltage output from 0 to rated voltage
when V/F is separated.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-18
V/F separation output voltage
deceleration time
0.0
~
3000.0s
1.0s
☆
This parameter is used to set the deceleration time of voltage output from rated voltage to 0
when V/F is separated.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-19
V/F separation and stop mode
selection
0
~
1
0
☆
0: Frequency and output voltage deceleration time are independent
;
1: After the voltage is reduced to 0, the frequency is reduced again
.
C
h
a
p
te
r
6