-87-
Chapter 5 Function & Parameter Table
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-15
Output voltage source
selection when VF is
separated
6: Communication given
7: PULSE pulse setting (Di5)
100.0% corresponds to the
rated voltage of the motor
0
☆
P2-16
V/F separation output voltage
digital setting
0V
~
Motor rated voltage
0V
☆
P2-17
V/F separation output voltage
acceleration time
0.0
~
3000.0s
1.0s
☆
P2-18
V/F separation output voltage
deceleration time
0.0
~
3000.0s
1.0s
☆
P2-19
V/F separation and stop
mode selection
0: Frequency and output
voltage deceleration time are
independent
1: After the voltage is
reduced to 0, the frequency
is reduced again
0
☆
Group P3: Vector control parameters
P3-00
Switching frequency P1
0.00
~
P3-02
5.00 Hz
☆
P3-02
Switching frequency P2
P3-00
~
P0-14
10.00 Hz
☆
P3-04
Low frequency speed
proportional gain
0.1
~
10.0
4.0
☆
P3-05
Low frequency speed
integration time
0.01s
~
10.00s
0.50s
☆
P3-06
High frequency speed
proportional gain
0.1
~
10.0
2.0
☆
P3-07
High frequency speed
integration time
0.01
~
10.00s
1.00s
☆
P3-08
Speed loop integral attribute
selection
0: Points take effect
1: Integral separation
0
★
P3-11
Torque current regulator Kp
0
~
30000
2200
☆
P3-12
Torque current regulator Ki
0
~
30000
1500
☆
P3-13
Excitation current regulator
Kp
0
~
30000
2200
☆
P3-14
Excitation current regulator
Ki
0
~
30000
1500
☆
P3-15
Flux Brake Gain
0
~
200
0
☆
C
h
a
p
te
r
5
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......