Chapter 4 Operation and Display
-64-
4.6.4.2 Parameter setting and operation of jog operation through DI port
On some production equipment that requires frequent jog operation, such as textile
machinery, it is more convenient to control jog with keys or buttons. The relevant
function code settings are as follows:
Figure 4-16
Schematic diagram of DI mode jog parameter setting
.
.
P0-04=1
DI
1
DI
2
DI
3
DI
4
DI
5
.
COM
P5-00
P5-01
P5-02
P5-03
P5-04
Forward jog
Forward
jog operation
Function
code
Port
Set value
Jog running
parameter setting
Terminal
command method
Reverse jog
Jog the control button
FJOG
RJOG
(
Stop state)
Jog/
positive
Jog/
reverse
4
.
.
5
.
.
F7-00 Jog running
frequency
F7-01 Jog
acceleration time
F7-02 Jog
deceleration time
Reverse
jog operation
After setting the relevant function code parameters as shown in the figure above,
when the inverter is stopped, press the FJOG button, the inverter will start to run
forward at low speed, release the FJOG button, the inverter will decelerate and
stop. Likewise, press the RJOG button for reverse jogging.
4.7 Frequency converter operating frequency control
There are 9 main frequency sources of the inverter, which are digital setting
(UP/DN power-off memory), digital setting (UP/DN power-off memory), AI1, AI2,
PULSE input, multi-segment instruction, simple PLC, PID , communication given,
etc., you can choose one of them by setting P0-06.
4.7.1 Main frequency given source selection
The inverter is set with 2 frequency given channels, named as main frequency so-
urce X and auxiliary frequency source Y respectively. They can work with a single
channel or can be switched at any time, and can even set the calculation method
for superposition and combination to meet the needs of the application site.
Different control requirements.
C
h
a
p
te
r
4
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......