Function
code
Name
Description
(setting range)
Factory
Default
Change
B4-02
Host sending frequency
selection:
0: Running frequency
1: Target frequency
0
★
B4-03
Slave follow master
command source selection
0: Do not follow
1: Follow
0
★
B4-04
Slave receive frequency
coefficient
0.00%
~
600.00%
100.00%
☆
B4-05
Slave receives torque
coefficient
-10.00
~
10.00
1.00
☆
B4-06
Slave receives torque bias
-50.00%
~
50.00%
0.00%
☆
B4-07
Frequency deviation
threshold
0.20%
~
10.00%
0.50%
☆
B4-08
Master-slave communication
drop detection time
0.00s
~
10.0s
0.1s
☆
Group B5: Brake function parameters
B5-00
Brake control enable
selection:
0: Disable
1: Enable
0
★
B5-01
brake release frequency
0.00Hz
~
20.00Hz
2.50Hz
★
B5-02
Brake release frequency
maintenance time
0.0s
~
20.0s
1.0s
★
B5-03
Current limit value during
holding brake
50.0%
~
200.0%
120.0%
★
B5-04
Brake pull-in frequency
0.00Hz
~
20.00Hz
1.50Hz
★
B5-05
Brake pull-in delay time
0.0s
~
20.0s
0.0s
★
B5-06
Holding time of brake pull-in
frequency
0.0s
~
20.0s
1.0s
★
Group B6: Sleep wakeup function parameters
B6-00
Hibernate selection
0: The sleep function is
invalid
1: Digital input terminal DI
controls sleep function
2: The sleep function is
controlled by the PID setting
value and feedback value
3: Control the sleep function
according to the operating
frequency
0
☆
C
h
a
p
te
r
5
-119-
Chapter 5 Function & Parameter Table
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......