Chapter 5 Function & Parameter Table
-88-
Function
code
Name
Description
(setting range)
Factory
Default
Change
P3-16
Field weakening torque
correction factor
50%
~
200%
100%
☆
P3-17
Slip compensation gain
50%
~
200%
100%
☆
P3-18
Speed loop feedback filter
time constant
0.000
~
1.000s
0.015s
☆
P3-19
Speed loop output filter time
constant
0.000
~
1.000s
0.000s
☆
P3-20
Electric torque upper limit
source
0: P3-21
1: AI1
2: AI2
3: Communication given
4: PLUSE given
(The analog range
corresponds to P3-21)
0
☆
P3-21
Electric torque upper limit
0.0%
~
200.0%
150.0%
☆
P3-22
Braking torque upper limit
source
0: P3-23
1: AI1
2: AI2
3: Communication given
4: PLUSE given
(The analog range
corresponds to P3-23)
0
☆
P3-23
Braking torque upper limit
0.0
~
200.0%
150.0%
☆
P3-24
Low-speed magnetizing
current of synchronous motor
0.0%
~
50.0%
25.0%
★
P3-25
Magnetizing cut-off frequency
of synchronous motor
0%
~
100%
10%
★
P3-26
Pre-excitation time
0s
~
5s
0.1s
★
P3-27
Synchronous motor initial
position identification enable
selection
0: Disable
1: Identification method one
2: Identification method 2
1
★
P3-28
Initial position identification
voltage given percentage
30%
~
130%
80%
★
Group P4: First motor parameter
P4-00
Motor parameter tuning
0: no function
1: Static tuning
2: Rotary tuning
0
★
C
h
a
p
te
r
5
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......