Chapter 6 Description of Function Codes
When used as a frequency source, PLC has three operating modes, which are not available
when used as a VF separation voltage source. in:
0: Stop at the end of a single operation
The inverter will automatically stop after completing a single cycle, and it needs to give the
running command again to start.
1: Keep the final value at the end of a single run
After the inverter completes a single cycle, it automatically maintains the running frequency
and direction of the last segment.
2: Keep looping
After the inverter completes one cycle, it will automatically start the next cycle until it stops
when there is a stop command.
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-17
PLC power-down memory
selection
0~3
0
☆
This function code determines the memory mode of the inverter when the inverter is powered
off when the PLC is running.
0: No memory when power off and no memory when stopped;
1: Memory when power off and no memory when stopped;
2: No memory when power off and memory when shut down;
3: Power-down memory and shutdown memory.
PLC power-off memory refers to the memory of the PLC's operating stage and operating fre-
quency before power-off, and continues to run from the memory stage when the power is
next turned on. If you choose not to remember, the PLC process will be restarted every time
the power is turned on.
PLC shutdown memory is to record the previous PLC running stage and running frequency
when it stops, and continue to run from the memory stage in the next running. If you choose
not to remember, the PLC process will be restarted each time it is started.
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-18
Running time of simple PLC multi-
speed 0
0.0s(h)
~
6500.0s(h)
0.0s(h)
☆
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......