-289-
Function
code
Name
Description
(setting range)
Factory
Default
Change
F6 Group
F06.00
S1 terminal function
selection
0: No function
1: Forward running
2: Reverse running
6: Free stop
12: Multi-speed terminal 1
13: Multi-speed terminal 2
14: Multi-speed terminal 3
51: Elevator overhaul signal
52 : Elevator emergency
signal
53: Short floor signal input
1
●
F06.01
S2 terminal function
selection
2
●
F06.02
S3 terminal function
selection
12
●
F06.03
S4 terminal function
selection
13
●
F06.04
S5 terminal function
selection
14
●
F06.05
S6 terminal function
selection
8
●
Group F07
F07.02
Relay TA output
selection
(
TA* TB* TC
)
3: Fault output;
42: Elevator brake output;
43: Operating contactor
output;
44: Emergency signal time
arrives (red font is new)
7
※
F07.03
Relay RA output
selection
(
RA* RB* RC
)
3
※
F07.04
Mo1 output selection
1
※
Group 26 Elevator special group
F26.00
Elevator-specific function
enable
0: invalid
1: valid
1
●
F26.01
Brake open delay
0.00 〜10.00s
0.00s
●
F26.02
Starting frequency
0.00 〜10.00Hz
5.00Hz
●
F26.03
Start frequency hold time
0.00 〜10.00s
0.00s
●
F26.04
brake closing frequency
delay
0.00 〜10.00s
0.30s
●
F26.05
Brake open frequency
(rising)
0.00 〜10.00Hz
1.00Hz
●
F26.06
Brake close frequency
(rising)
0.00 〜10.00Hz
0.20Hz
●
C
h
a
p
te
r
1
0
Chapter 10 Appendix
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......