-177-
Chapter 6 Description of Function Codes
This parameter refers to the drop value of the output frequency when the inverter outputs the
rated load.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-19
Delay time for frequency lower
than lower limit shutdown
0.0s
~
600.0s
0.0s
☆
When the set frequency is lower than the lower limit frequency and the action is selected as
stop, the action of P7-19 will be delayed.
Preset the running time of the inverter. When set to 0, this function has no effect.
When the accumulated running time (P7-34) reaches the set running time, the multi-function
digital terminal of the inverter outputs the running time arrival signal (multi-function output No.
26) ON signal, and the inverter reports the accumulated time arrival fault Err40 at the same
time.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-20
Set cumulative operating time
0h
~
65000h
0h
☆
0: invalid
1: Jog priority mode 1
2: Jog priority mode 2
1) When the user fails or the PID is lost, the jog is still valid;
2) The stop mode and DC braking can be set.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-21
Jog priority
0~2
1
☆
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-22
Frequency detection value (PDT1
level)
0.00Hz
~
Maximum
frequency
50.00Hz
☆
P7-23
Frequency check hysteresis value
(PDT1 hysteresis)
0.0%
~
100.0%
5.0%
☆
C
h
a
p
te
r
6