![Vicruns 2S-0.4G-B User Manual Download Page 226](http://html1.mh-extra.com/html/vicruns/2s-0-4g-b/2s-0-4g-b_user-manual_1013433226.webp)
Chapter 6 Description of Function Codes
-225-
Group A2: Second motor VF parameter setting
The detailed description of the function code parameters of this group is consistent with the
P2 group. For the VF control function codes not listed in this group, the P2 group is directly
used.
Function
code
Name
Description
(setting range)
Factory
Default
Change
A2-00
Torque boost
0.0%
~
30.0%
0.0%
☆
When the parameter is set to 0, it means automatic torque boost.
Function
code
Name
Description
(setting range)
Factory
Default
Change
A2-01
Oscillation suppression gain
0
~
100
Model is
determined
☆
Group A3: Second motor vector control parameters
The function of this group of parameters is similar to the parameters of group P3, which is va-
lid when the motor is the second motor. For detailed function code description, please refer to
the description of function code of group P3.
Function
code
Name
Description
(setting range)
Factory
Default
Change
A3-00
Switching frequency P1
1.00Hz
~
A3-02
5.00Hz
☆
A3-02
Switching frequency P2
A3-00
~
P0-14
10.00Hz
☆
A3-04
Low frequency speed proportional
gain
0.1
~
10.0
4.0
☆
A3-05
Low frequency speed integration
time
0.01s
~
10.00s
0.50s
☆
A3-06
High frequency speed proportional
gain
0.1
~
10.0
2.0
☆
A3-07
High frequency speed integration
time
0.01s
~
10.00s
1.00s
☆
A3-08
Speed loop integral attribute
selection
0~1
0
★
A3-11
Torque current regulator Kp
0
~
30000
2000
☆
C
h
a
p
te
r
6
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......