Chapter 5 Function & Parameter Table
-102-
Function
code
Name
Description
(setting range)
Factory
Default
Change
4: 4800BPS
5: 9600BPS
6: 19200BPS
7: 38400BPS
P8-01
Data Format
0: No parity <8,N,2>
1: Even parity <8,E,1>
2: odd parity <8,O,1>
3: No parity 1<8,N,1>
0
☆
P8-02
Mailing address
0
~
247 (0 is the broadcast
address)
1
☆
P8-03
Response time
0ms
~
30ms
2ms
☆
P8-04
Communication timeout
0ms
~
30ms
0.0s
☆
P8-05
Communication format
selection
0: Standard ModbusRTU protocol
1: Non-standard ModBusRTU
protocol
0
☆
P8-06
Background software
monitoring function
0: Disable, default 485
communication function
1: On, the background software
monitoring function, the 485
communication function cannot be
used at this time
0
☆
Group P9: Fault and Protection
P9-00
Motor overload
protection selection
0: Disable
1: Allow
1
☆
P9-01
Motor overload
protection gain
0.20
~
10.00
1.00
☆
P9-02
Motor overload warning
coefficient (℅)
50%
~
100%
80%
☆
P9-03
Overvoltage Stall
Protection Gain
000
~
100
030
☆
P9-04
Overvoltage stall
protection voltage
200.0
~
850.0V
760.0V
★
P9-05
VF Overcurrent Stall
Protection Gain
0
~
100
20
☆
P9-06
VF Overcurrent Stall
Protection Current
50%
~
200%
150%
★
C
h
a