![Vicruns 2S-0.4G-B User Manual Download Page 258](http://html1.mh-extra.com/html/vicruns/2s-0-4g-b/2s-0-4g-b_user-manual_1013433258.webp)
Chapter 9 Troubleshooting and Countermeasures
-257-
C
h
a
p
te
r
9
Fault
name
Panel
display
Troubleshooting
Troubleshooting
Countermeasures
Overcur
rent
during
deceler
ation
Err05
u
There is grounding or short circuit
in the output circuit of the inverter
u
The motor parameters are
incorrect
u
The deceleration time is too short
u
The input voltage is low
u
Sudden load during deceleration
u
No braking unit and braking
resistor
u
The magnetic flux braking gain is
too large
u
Eliminate peripheral faults
u
Perform motor parameter
identification
u
Increase the deceleration
time
u
Adjust the voltage to the
normal range
u
Cancel sudden load
u
Install braking unit and
resistance
u
Reduce the magnetic flux
braking gain
Overcur
rent in
constan
t speed
operatio
n
Err06
u
There is grounding or short circuit
in the output circuit of the inverter
u
The motor parameters are
incorrect
u
The input voltage is low
u
Is there a sudden load during
operation?
u
Inverter selection is too small
u
Eliminate peripheral faults
u
Check parameters and
parameter identification
u
Adjust the voltage to the
normal range
u
Cancel sudden load
u
Select the inverter with a
larger power level
Overvol
tage
during
acceler
ation
Err08
u
The input voltage is too high
u
There is an external force driving
the motor to run during the
acceleration process
u
The acceleration time is too short
u
No braking unit and braking
resistor
u
The motor parameters are
incorrect
u
Adjust the voltage to the
normal range
u
Cancel external power or
install braking resistor
u
Increase the acceleration
time
u
Install braking unit and
resistor
u
Check parameters and
parameter identification
Overvol
tage
during
deceler
ation
Err09
u
The input voltage is too high
u
There is an external force driving
the motor to run during the
deceleration process
u
The deceleration time is too short
u
No braking unit and braking
resistor
u
Adjust the voltage to the
normal range
u
Cancel external power or
install braking resistor
u
Increase the deceleration
time
u
Install braking unit and
resistor