Function
code
Name
Description
(setting range)
Factory
Default
Change
A3-13
Excitation current
regulator Kp
0
~
30000
2000
☆
A3-14
Excitation current
regulator Ki
0
~
30000
1300
☆
A3-15
Flux Brake Gain
100
~
200
110
☆
A3-16
Field weakening torque
correction factor
50%
~
150%
100%
☆
A3-17
Slip Compensation
Coefficient
50%
~
200%
100%
☆
A3-18
Speed loop feedback
filter time constant
0.000s
~
1.000s
0.015s
☆
A3-19
Speed loop output filter
time constant
0.000s
~
1.000s
0.000s
☆
A3-20
Electric torque upper limit
source
0: P3-21
2: AI2
1: AI1 (analog range
corresponds to P3-21)
3: Communication given
4: PLUSE given
0
☆
A3-21
Electric torque upper limit 0.0%
~
200.0%
150.0%
☆
A3-22
Braking torque upper limit
source
0: P3-23
2: AI2
1: AI1 (analog range
corresponds to P3-23)
3: Communication given
4: PLUSE given
0
☆
A3-23
Braking torque upper limit
0.0%
~
200.0%
150%
☆
Group B0: System parameters
B0-00
Function code read-only
selection
0: invalid
1: read only
0
☆
B0-01
LCD top menu
display/LED second line
display
0: output current
1: Motor speed
2: Load speed
3: Output voltage
4: PID given
5: PID feedback
0
☆
C
h
a
p
te
r
5
-115-
Chapter 5 Function & Parameter Table
Summary of Contents for 2S-0.4G-B
Page 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Page 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Page 126: ...Function Parameter Table Chapter 6...
Page 245: ......
Page 249: ......
Page 255: ......