This document is supplied with Model KBVF-22D (Part No. 9572).

IMPORTANT: The following information and instructions are to be used as a supplement to the KBVF Installation and Operation Manual (Part
No. A40288) until the new manual is available with the addition of Model KBVF-22D (Part No. 9572).  The  KBVF Series has been changed to
a second generation version (2G).  The General Performance Specifications have not changed.  This 2G version has an additional Frequency
Multiplier Jumper, a single Input Line Voltage Selection Jumper, and an additional connector for accessories.  The KBVF manual must be read
and understood before attempting to operate this control.  For further assistance, contact our Sales Department at 954-346-4900 or Toll Free
at 800-221-6570 (outside Florida).
Also see KBVF 2G Version Supplemental Connection Diagrams and Jumper Settings (Part No. A40090G).

Table 1 - Electrical Ratings

AC Line Input

Motor Output

Model

Part No.

Volts AC

(50/60 Hz)

Maximum

Current

(Amps AC)

Voltage Range

(Volts AC)

Maximum

Continuous Load Current

(RMS Amps/Phase)

Maximum

Horsepower

(HP (kW))

115

6.0

KBVF-22D

9572

208/230

3.8

0 - 230

  1.5 *

¼ (.18)

* CL Trimpot Range (Amps AC): 0.9 - 2.8 (Factory Setting: 2.4).

Figure 1 - Mechanical Specifications (Inches/mm) and Control Layout

(Shown without Factory Installed Finger-Safe Cover)

Enlarged View of Jumpers and Trimpots

1

Setting Selectable Jumpers
This control has selectable jumpers which may have to be set  before  the control can  be  used.   See Figure  1,  above,  for  the location  of
jumpers.  WARNING! Disconnect the AC line before changing position of jumpers.
See Section III, on pages 14 - 16 of the manual.

1.1

AC Line Input Voltage Selection (Jumper J1 on Upper PC Board): This control can operate standard 208 - 230 Volt AC - 50/60

 

 "!#!%$&'()*'(,+-.

/"$(0*1#(234!

5768.

9

:#;3< =.

,>?

@3=:/>&AB>

208/230 Volt AC line input (Jumper J1 in the "230V" position).  To operate the control from a 115 Volt AC line input, set Jumper J1
to the "115V" position.  See Figure 2, on page 2.

Summary of Contents for KBVF Series

Page 1: ...4900 or Toll Free at 800 221 6570 outside Florida Also see KBVF 2G Version Supplemental Connection Diagrams and Jumper Settings Part No A40090G Table 1 Electrical Ratings AC Line Input Motor Output Mo...

Page 2: ...osition To operate 50 Hz motors up to 100 Hz set Jumper J1 to the 50Hz position and set Jumper J2 to the X2 position Note In Overspeed Mode the motor will produce full rated torque up to the motor s r...

Page 3: ...tatus Indicator 22 IX Trimpot Adjustments 24 X Limited Warranty 30 TABLES 1 General Performance Specifications 5 6 2 Electrical Ratings 7 3 Terminal Wiring Information 17 4 Fuse Selection Chart 21 5 K...

Page 4: ...control chassis 2 MOTOR LEADS Connect the three motor leads to terminals U V and W Be sure motor is wired for proper voltage 208 230VAC only Motor cable length should not exceed 100 feet special react...

Page 5: ...es pertinent at the time of manufacture Contact factory for detailed installation instructions and Declaration of Conformity Installation of a CE approved RFI filter KBRF 200A KB P N 9945A or equivale...

Page 6: ...of frequency setting 70 110 100 Speed Range ratio 50 1 Isolated Input Signal must be used 5 General Performance Specifications Continued Parameter Specification Factory Setting Acceleration Trimpot R...

Page 7: ...over a wider speed range Consult motor manufacturer for details WARNING There may be some motors whose characteristics may cause overheating and winding failure under light load or no load conditions...

Page 8: ...FIG 3 CONTROL LAYOUT Illustrates factory setting of jumpers and approximate setting of trimpots 9 FIG 4A KBVF HP MECHANICAL SPECIFICATIONS INCHES mm 10...

Page 9: ...FIG 4B KBVF HP MECHANICAL SPECIFICATIONS INCHES mm 11 FIG 5A KBVF 1 HP MECHANICAL SPECIFICATIONS INCHES mm 12...

Page 10: ...LTS Warning Do not change jumper position with AC line connected Be sure proper input voltage is applied to control corresponding to jumper setting Connecting 230VAC to a 115VAC control input will per...

Page 11: ...green to Red Yellow flash approximately 15 seconds 2 Turning the main speed pot to zero MIN speed trimpot must be set to zero speed in order to reset with main speed pot 3 Use Enable contact See secti...

Page 12: ...Designation Connection Designation Type of Connector Supply Wire Gauge Minimum Maximum AC Line L1 L2 1 4 QD 16 14 Motor U V W 1 4 QD 16 14 Potentiometer P1 P2 P3 1 4 QD 22 18 17 A AC Line Wire the co...

Page 13: ...impot must be turned to zero CCW If 0 10VDC operation is required a resistor network can be added as per fig 10C If an isolated signal is not available a separate signal isolator must be used KBSI 240...

Page 14: ...y proper operation See sec VIII p 22 21 TABLE 5 KBVF STATUS INDICATORS LED Ref Function State 1 LED Color ST Status Normal Control Operation Slow Flash Green CL current limit Steady Red I2 t Quick Fla...

Page 15: ...e controls contain trimpots which have been factory adjusted for most applications Paragraph 4 on page 2 illustrates the location of the trimpots and their approximate adjustment positions Some applic...

Page 16: ...red for application Note When the control is set for 50 Hz operation the DEC trimpot will automatically change to Adjustable Boost See sec IX G p 28 25 Application Note On applications with high inert...

Page 17: ...ies with one motor phase 27 2 Run motor and set unloaded speed to approximately 50 speed 900 RPM on 4 pole 1500 1725 RPM motors Using a tachometer record unloaded speed 3 Load motor to rated motor nam...

Page 18: ...o be defective in material or workmanship This warranty is valid if the unit has not been tampered with by unauthorized persons misused abused or improperly installed and has been used in accordance w...

Reviews: