V2
V2
V2
V2
V4
V4
V4
V4
V1
V1
0V
0V
−V1
−V1
COM0
COM1
S0
S1
COM0
COM1
COM2
COM3
COM4
COM5
COM6
COM7
S0
S1
off
on
COM1-S1
Segment is off.
COM0-S0
Segment is on.
V1
V1
V1
V1
V5
V5
V5
V5
f
frame
*
*
*
*
*
*
*
*
LCD_F Controller Architecture and Operation
1013
SLAU356I – March 2015 – Revised June 2019
Copyright © 2015–2019, Texas Instruments Incorporated
LCD_F Controller
shows some example 8-mux 1/3-bias waveforms with LCDLP = 1. With LCDLP = 1, the
voltage sequence compared to the non-low power waveform is reshuffled; that is, all of the timeslots
marked with "*" in
are grouped together. The same principle applies to all mux modes.