System Controller A (SYSCTL_A)
5.9.3.2
Temperature Sensor Calibration
The temperature sensor calibration data is available as part of the ADC calibration descriptor (see
Table 5-7. ADC Calibration Data
ADC Calibration
Tag
00000005h
Length
00000018h
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
Reserved
Word
CAL_ADC_12T30
Word
CAL_ADC_12T85
Word
CAL_ADC_145T30
Word
CAL_ADC_145T85
Word
CAL_ADC_25T30
Word
CAL_ADC_25T85
The temperature sensor is calibrated using the internal voltage references. Each reference voltage (1.2 V,
1.45 V, or 2.5 V) contains a measured value for two temperatures, 30°C ±3°C and 85°C ±3°C, stored in
the TLV structure.
shows the characteristic equation of the temperature sensor voltage, in
millivolts.
where
•
TC
SENSOR
, in mV/°C, is the temperature coefficient and represents the slope of the equation.
•
V
SENSOR
, in mV, represents the y-intercept of the equation.
•
Temp, in °C, is the temperature of interest.
(3)
The temperature (Temp, °C) can be computed by
for each of the reference voltages used in
the ADC measurement: