0h
0FFFFh
EQU0
TAIFG
Output Mode 1: Set
Output Mode 2: Toggle/Reset
Output Mode 3: Set/Reset
Output Mode 4: Toggle
Output Mode 5: Reset
Output Mode 6: Toggle/Set
Output Mode 7: Reset/Set
TAxCCR0
TAxCCR1
EQU1
EQU0
TAIFG
EQU1
EQU0
TAIFG
Interrupt Events
Timer_A Operation
792
SLAU356I – March 2015 – Revised June 2019
Copyright © 2015–2019, Texas Instruments Incorporated
Timer_A
19.2.5.1.1 Output Example—Timer in Up Mode
The OUTn signal is changed when the timer
counts
up to the TAxCCRn value and rolls from TAxCCR0 to
zero, depending on the output mode.
shows an example using TAxCCR0 and TAxCCR1.
Figure 19-12. Output Example – Timer in Up Mode