![Rohde & Schwarz 1321.0615.02 User Manual Download Page 395](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771395.webp)
Remote Commands
R&S
®
Spectrum Rider FPH
388
User Manual 1321.1011.02 ─ 11
1
Transducer is an isotropic antenna.
Example:
CORR:TRAN:ISOT?
only an example
13.6.3
Remote Commands of the Analog Modulation
The chapter provides information on remote commands that configure and perform
analog modulation measurements.
Availability of remote commands for the analog modulation
Note that the listed remote commands take effect only if R&S FPH-K7 is installed on
the R&S Spectrum Rider
...........................................................................................388
...................................................................................... 389
......................................................................................... 392
....................................................................................393
.....................................................................................394
..................................................................................... 395
............................................................................396
Reading out Measurement Results
.......................................................................398
13.6.3.1
Setting the Frequency
The following chapter describes command to define and query on the frequency set-
tings
List of commands
......................................................................................... 388
................................................................................389
[SENSe:]FREQuency:CENTer
<CenterFrequency>
This command defines the center frequency of the R&S Spectrum Rider.
In spectrum analyzer mode, the command also defines the measuring frequency for
time domain measurements (span
=
0).
Parameters:
<CenterFrequency> Range:
Depends on the operating mode and is specified in
the data sheet.
*RST:
fmax /2 with fmax = maximum frequency
Default unit: MHz
Example:
FREQ:CENT 100MHz
Defines a center frequency of 100 MHz.
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH