![Rohde & Schwarz 1321.0615.02 User Manual Download Page 373](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771373.webp)
Remote Commands
R&S
®
Spectrum Rider FPH
366
User Manual 1321.1011.02 ─ 11
Example:
CALC:MARK:FUNC:CPOW:BAND 4 MHZ
Sets the channel bandwidth to 4 MHz.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:MODE
<DisplayMode>
This command selects the display mode for channel power measurements.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Parameters:
<DisplayMode>
CLR | MAX
CLR
Displays the currently measured value (Clear / Write).
MAX
Displays the highest measured value (Max Hold).
*RST:
CLR
Example:
CALC:MARK:FUNC:CPOW:MODE CLR
Selects clear/write power display mode.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:UNIT
<Unit>
This command selects the unit of the vertical axis for channel power measurements.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Suffix:
<1...2>
.
1...2
<1...6>
1...6
Parameters:
<Unit>
DBM | DBMV | DBUV | DUVE | DMVE | VEMF | DBUA | VOLT |
WATT | DUVM | DUAM | V | W | V_M | W_M2
*RST:
dBm
Example:
CALC:MARK:FUNC:CPOW:UNIT DBM
Sets the unit to dBm.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:POWer:RESult:PHZ
<State>
This command turns the display of the channel power per Hertz on and off.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Parameters:
<State>
ON |OFF
*RST:
dBm
Example:
CALC:MARK:FUNC:POW:RES:PHZ ON
Displays the measured Channel Power / Hz.
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH