![Rohde & Schwarz 1321.0615.02 User Manual Download Page 385](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771385.webp)
Remote Commands
R&S
®
Spectrum Rider FPH
378
User Manual 1321.1011.02 ─ 11
CALCulate<1...2>:LIMit<1...2>:ACPower:STATe
<State>
This command turns the limit check for ACLR measurements on and off.
You have to use
CALCulate<1...2>:LIMit<1...2>:ACPower:ACHannel[:
CALCulate<1...2>:LIMit<1...2>:
ACPower:ALTernate<1...11>[:RELative]:STATe
with this command to select the channels the limit check should be performed on.
The suffix at CALCulate and LIMit are irrelevant for this command.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:LIM:ACP ON
Activates the limit check.
CALCulate<1...2>:LIMit<1...2>:ACPower:ACHannel[:RELative]
<RelativeLimit>
This command defines the relative limit of the adjacent channels. The reference value
for the relative limit value is the measured channel power.
Note that the relative limit has no effect on the limit check if it is below the absolute limit
value (see
CALCulate<1...2>:LIMit<1...2>:ACPower:ACHannel:ABSolute
on page 379. This mechanism allows automatic checking of the absolute basic values
of adjacent-channel power as defined in mobile radio standards.
The suffix at CALCulate and LIMit are irrelevant for this command.
Parameters:
<RelativeLimit>
Range:
0 dB to 100 dB
Default unit: dB
Example:
CALC:LIM:ACP:ACH 30
Defines a limit of 30 dB.
CALCulate<1...2>:LIMit<1...2>:ACPower:ACHannel[:RELative]:STATe
<State>
This command turns the relative limit check for the adjacent channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<1...2>:LIMit<1...2>:ACPower:STATe
The suffix at CALCulate and LIMit are irrelevant for this command.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:LIM:ACP:ACH:STAT ON
Activates the relative limit check.
Remote Control - Commands
www.allice.de