![Rohde & Schwarz 1321.0615.02 User Manual Download Page 344](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771344.webp)
Remote Commands
R&S
®
Spectrum Rider FPH
337
User Manual 1321.1011.02 ─ 11
It also transfers data from a file to a particular trace.
on page 335, you can set the data format.
on page 397, you can selects the
result display.
The numeric suffix at TRACe is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<arg0>
TRACe1 | TRACe2 | LIST | PHOLd | RAW
TRACe1
Queries the data of trace 1.
TRACe2
Queries the data of trace 2.
LIST
Queries the peak list of the measurement.
PHOLd
Queries the scanned peak hold list in the receiver mode mea-
surement.
RAW
Queries the raw FSK/ASK data in the analog demodulation
mode measurement.
The R&S Spectrum Rider returns 711 values. Each value corre-
sponds to one pixel of a trace.
The unit depends on the measurement and the unit you have
set with
UNIT<1...2>:POWer
.
Note: If you use the auto peak detector, the command reads out
positive peak values only.
Example:
TRAC:DATA? TRACE1
Reads out the data for trace 1.
Usage:
Query only
TRACe<1...2>[:DATA]:MEMory?
[<arg0>]
Read memory trace data.
The numeric suffix at TRACe is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<arg0>
Example:
CALC:MATH:COPY:MEM
TRAC:MEM?
Copy trace1 to memory1 and read memory1 trace data.
Remote Control - Commands
www.allice.de